Fire Protection
We are leaders in the design, installation, and preventive and corrective maintenance of active protection systems. We guarantee maximum structural safety through cutting-edge technology and strict compliance with regulations.
Supply Systems
At the heart of any fire protection system is its water source and pump station. We design reserve tanks and pump rooms in accordance with UNE-EN 12845 and NFPA standards.
Electric Pump
The main driver of operational workflow.
Diesel Pump
Autonomous backup in the event of power outages.
Jockey Pump
Maintaining constant pressure in the network.
BIEs: Equipped Fire Hydrants
Essential first-response equipment for trained users. We guarantee immediate access and certified operational readiness in accordance with current regulations.
General-purpose use for non-specialized personnel. It offers semi-rigid hoses that are easy to deploy without the risk of strangulation.
Intended for fire brigades or firefighters. Requires flat hoses and a higher water flow rate for critical operations.
Automatic Sprinklers
Automatic fire suppression systems designed to control or extinguish fires in their early stages without human intervention.
Wet Pipe
Immediate response: the pipe is constantly pressurized with water.
Dry Pipe
Ideal for areas at risk of freezing; water only enters after activation.
Pre-action
Dual safety feature: requires both smoke detection and thermal cutout activation.
Fire Extinguisher Manual
Careful selection based on the type of fuel for effective fire suppression.
A
Solids
Wood, paper, cardboard, plastics, and fabrics.
B
Liquids
Gasoline, oils, paints, or alcohols.
C
Gases
Butane, propane, or city gas.
D
Metals
Magnesium, sodium, or potassium.
E
Kitchen
Vegetable or animal oils and fats.
Photoluminescent Signage
In conditions of zero visibility due to smoke or a power outage, our Class A and B signs guide people to safety. They strictly comply with UNE 23035.
- High brightness in total darkness.
- Fire-resistant and heat-resistant materials.
- International standard iconography.
Lithium-Ion Risk
Essential first-response equipment for trained users. We guarantee immediate access and certified operational readiness in accordance with current regulations.
Prevention of thermal runaway using F-500 encapsulating agents that penetrate the battery module.
Neutralization of flammable gases emitted during the degradation of lithium cells.
Design of secure storage chambers for electric vehicles and data centers.
Outdoor Infrastructure and Fire Department
Systems designed exclusively for professional firefighting operations, ensuring access points and a large-scale water supply.
Dry / Wet Column
For fire department use only. Facilitates the transport of water through the floors of a building without having to lay out hoses on the stairs. Essential in high-rise buildings.
Fire Hydrants
Outdoor connections that supply large volumes of water. Available in dry-pipe (freeze-resistant), wet-pipe, and underground (manhole) versions.